How the OnBoard Manages Communications With Devices
366 AlterPath OnBoard Administrator’s Guide
All Expect scripts reside in /libexec/onboard, as shown in the
following listing.
The files fall into three categories:
talk_devicetype.exp scripts are the Expect scripts for the
various types of service processors.
talk_custom[1-3].exp scripts are placeholders.
The administrator can create a customized Expect script by copying,
renaming, and modifying talk_generic.exp,
talk_generic_ipmi.exp or one of the default Expect scripts. The
administrator should set the file permissions to allow reading and
execution by all users and writing by members of the admin group. The
format of a custom Expect script’s file name should be:
talk_customN.exp.
Up to a total of three custom Expect scripts are supported. They must
use the names of the placeholder custom scripts.
[root@OnBoard /]
cd /libexec/onboard/
[root@OnBoard /]# ls
bidi_login.exp sensors.exp
talk_generic_ipmi.exp
common.exp ssh_login.exp talk_ilo.exp
gen_logrotate.sh talk_custom1.exp talk_ipmi_1.5.exp
local_log.exp talk_custom2.exp talk_rsa_I.exp
locking.exp talk_custom3.exp talk_rsa_II.exp
onbdauth talk_devconsole.exp template.exp
onbdunesc talk_drac.exp
poll_sensors.sh talk_generic.exp